BC-700 Series
SF Cube · Hybrid Channel PLT · Easy-W ESR
Above your expectations
SF Cube fluorescent technology allows reliable counting and differentiation of abnormal samples
Beyond your expectations
Optical PLT-H in every CBC + DIFF test
In order to solve the above problem, we have developed a brand new parameter PLT-H.
It combines small PLTs from the conventional impedance method and large PLTs from the optical method. The solution can resist the interferences in conventional PLT detection without requiring extra reagents.
Easy-W ESR
CBC + DIFF + ESR in one test provide reliable ESR results with greater ease
The BC-700 series integrates an automatic ESR module in a hematology analyzer. It can also generate both CBC & ESR results in one test within 1.5 min. In addition, it saves the costs that would otherwise be incurred for the purchase, maintenance, consumables, and storage space of a separate ESR analyzer. Compared with the traditional Westergren method, this method performs better in quality traceability, repeatability, speed, safety, and level of automation.
- Great correlation with the Westergren method
- Same QC and calibrator as in the BC-6000 series
- Combined examination helps to avoid the interferences of dehydration, polycythemia vera and anemia on ESR results
- The integrated instrument is capable of both CBC and ESR detection
- Takes up the space of only one analyzer
- Report CBC + ESR results together within 1.5 min
- The measurement results are protected against the influence of subjective factors
- Automation can reduce the biosafety hazards that may otherwise be introduced by a manual method
Excellent performance, high reliability, and ease of use
The BC-700 series integrates an automatic ESR module in a hematology analyzer. It can also generate both CBC & ESR results in one test within 1.5 min. In addition, it saves the costs that would otherwise be incurred for the purchase, maintenance, consumables, and storage space of a separate ESR analyzer. Compared with the traditional Westergren method, this method performs better in quality traceability, repeatability, speed, safety, and level of automation.
- Great correlation with the Westergren method
- Same QC and calibrator as in the BC-6000 series
- Combined examination helps to avoid the interferences of dehydration, polycythemia vera and anemia on ESR results
- The integrated instrument is capable of both CBC and ESR detection
- Takes up the space of only one analyzer
- Report CBC + ESR results together within 1.5 min
- The measurement results are protected against the influence of subjective factors
- Automation can reduce the biosafety hazards that may otherwise be introduced by a manual method
An all-in-one solution that goes above and beyond your expectations
Related Product
Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research.
At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/RET/body fluid results generated in a small-footprint system, among others, all within limited budget.